Railway Control System

Relay



  •  Neutral Relay
  •  Interlock Relay
  •  Lamp Proving Relay
  •  Special Types Relays
Relay Type : TMA 1144/111 - GUM
TMA 1153/111 - GUM
TMA 1162/111 - GUM
TMA 1126/111 - GUM
TMA 1124/111 - GUM
TMA 1122/111 - GUM
Relay Ratings : 60 V DC +/- 20%.
Contact Configuration :
4F/4B; 5F/3B; 6F/2B; 2F/6B;F/4B; 2F/2B & any other contact  combination of 8 contacts.
Relay Mounting : With or without plug-in-base & with socket.
Pick Up Value : < / = 48 V DC & > / = 16 mA.
Drop Off Value : > / = 12 V DC & 5 mA.
Neutral Relay 60 V DC
Download Brochure